Anchor UNO Automatic Changover (ACCL) TPN
Product Description
-
A changeover device, which on failure of Mains power supply, automatically transfers the Load from Mains power supply to Generator supply
-
It also functions as a Load Limiter with monitoring of current drawn from Generator, thereby reducing stress on the Generator
-
Features
-
UL marked robust contactors design
-
Compact size saving panel space
-
Dual Interlock between Mains & Gen supply (Electrical & Mechanical)
-
Manual & Remote reset provision
-
Automatic Generator Start/Stop
-
Overload monitoring of Generator supply
-
Indication of status through coloured LED
-
Break before make changeover system
Product Specification
|
Brand |
Anchor |
|
Product Type |
Automatic Changeover |
|
Series |
UNO |
|
Product Code | Specification |
98615 | 40A/6A UNO TPN/SPN ACCL 98616 | 40A/10A UNO TPN/SPN ACCL 98617 | 40A/16A UNO TPN/SPN ACCL 98618 | 40A/20A UNO TPN/SPN ACCL 98619 | 40A/25A UNO TPN/SPN ACCL 98620 | 40A/32A UNO TPN/SPN ACCL 98621 | 40A/40A UNO TPN/SPN ACCL 98630 | 40A/6A UNO TPN/TPN ACCL 98631 | 40A/10A UNO TPN/TPN ACCL 98632 | 40A/16A UNO TPN/TPN ACCL 98633 | 40A/20A UNO TPN/TPN ACCL 98634 | 40A/25A UNO TPN/TPN ACCL 98635 | 40A/32A UNO TPN/TPN ACCL 98636 | 40A/40A UNO TPN/TPN ACCL |
|
Standard Conformity |
IEC 60947-6 |
|
Versions |
TPN/SPN and TPN/TPN |
|
Mains Current & Voltage |
40A & 415V ~ (P-P) |
|
Gen Current & Voltage |
6-40A & 230V~(P-N) & 6-40A & 415V ~(P-P) |
|
Frequency |
50Hz |
|
Rated Impulse Voltage(Uimp) |
6kV |
|
Duty |
Continuous duty |
|
Utilization Category |
AC32A |
|
Conditional Short Circuit |
5kA |
|
Electrical Life |
25000 ops. |
|
Power Consumption |
<8VA (Mains/ GEN) |
|
Protection |
IP20 (Terminal Enclosure) |
|
Pollution Degree |
III |
|
Operating Temperature |
-5 to 55°C |
|
Mounting |
Panel mounting |
|
Weight |
2.3kg (Unpacked) |
|
Operating Position |
Horizontal/ Vertical |
|
Tripping Accuracy |
± 5-10% of Trip current |
|
Timing Accuracy |
±5% |
|
Warranty |
As Per Manufacturer Terms & Conditions |
Original: $156.92
-70%$156.92
$47.08
Description
Product Description
-
A changeover device, which on failure of Mains power supply, automatically transfers the Load from Mains power supply to Generator supply
-
It also functions as a Load Limiter with monitoring of current drawn from Generator, thereby reducing stress on the Generator
-
Features
-
UL marked robust contactors design
-
Compact size saving panel space
-
Dual Interlock between Mains & Gen supply (Electrical & Mechanical)
-
Manual & Remote reset provision
-
Automatic Generator Start/Stop
-
Overload monitoring of Generator supply
-
Indication of status through coloured LED
-
Break before make changeover system
Product Specification
|
Brand |
Anchor |
|
Product Type |
Automatic Changeover |
|
Series |
UNO |
|
Product Code | Specification |
98615 | 40A/6A UNO TPN/SPN ACCL 98616 | 40A/10A UNO TPN/SPN ACCL 98617 | 40A/16A UNO TPN/SPN ACCL 98618 | 40A/20A UNO TPN/SPN ACCL 98619 | 40A/25A UNO TPN/SPN ACCL 98620 | 40A/32A UNO TPN/SPN ACCL 98621 | 40A/40A UNO TPN/SPN ACCL 98630 | 40A/6A UNO TPN/TPN ACCL 98631 | 40A/10A UNO TPN/TPN ACCL 98632 | 40A/16A UNO TPN/TPN ACCL 98633 | 40A/20A UNO TPN/TPN ACCL 98634 | 40A/25A UNO TPN/TPN ACCL 98635 | 40A/32A UNO TPN/TPN ACCL 98636 | 40A/40A UNO TPN/TPN ACCL |
|
Standard Conformity |
IEC 60947-6 |
|
Versions |
TPN/SPN and TPN/TPN |
|
Mains Current & Voltage |
40A & 415V ~ (P-P) |
|
Gen Current & Voltage |
6-40A & 230V~(P-N) & 6-40A & 415V ~(P-P) |
|
Frequency |
50Hz |
|
Rated Impulse Voltage(Uimp) |
6kV |
|
Duty |
Continuous duty |
|
Utilization Category |
AC32A |
|
Conditional Short Circuit |
5kA |
|
Electrical Life |
25000 ops. |
|
Power Consumption |
<8VA (Mains/ GEN) |
|
Protection |
IP20 (Terminal Enclosure) |
|
Pollution Degree |
III |
|
Operating Temperature |
-5 to 55°C |
|
Mounting |
Panel mounting |
|
Weight |
2.3kg (Unpacked) |
|
Operating Position |
Horizontal/ Vertical |
|
Tripping Accuracy |
± 5-10% of Trip current |
|
Timing Accuracy |
±5% |
|
Warranty |
As Per Manufacturer Terms & Conditions |