Anchor UNO Automatic Changover (ACCL) SPN
Product Description
-
A changeover device transfers the Load from Mains power supply to the Generator, automatically upon failure of Mains power supply
-
It also functions as a Load limiter with monitoring of the Generator supply, thereby reducing stress on the Generator
Product Specification
|
Brand |
Anchor |
|
Product Type |
Automatic Changeover |
|
Series |
UNO |
|
Product Code | Gen Current Rating(In) |
98600 | 0.5A 98601 | 1A 98602 | 1.5A 98603 | 2.5A 98605 | 4A 98606 | 5A 98607 | 6A 98608 | 9A 98612 | 10A 98609 | 12A 98610 | 15A 98611 | 20A 98613 | 25A 98614 | 30A |
|
Standard Conformity |
IEC 60947-3/ IEC 60947-6 |
|
Poles |
SPN |
|
Mains Current Rating(In) |
30A |
|
Gen Current Rating(In) |
0.5A to 30A |
|
Rated Voltage (Ue) |
240V~AC, 50Hz |
|
Rated Impulse Voltage |
2.5kV |
|
Design |
Contactor Based Design |
|
Housing Material |
Thermoplastic, FR Grade |
|
Class Of Equipment |
PC |
|
Duty |
Continuous |
|
Utilisation Category |
AC22A(IEC 60947-3), AC32A (IEC 60947-6) |
|
Conditional Short-Circuit Current(Inc) |
5kA |
|
Electrical Life |
25000 Operations |
|
Power Losses |
0.2 VA Mains, 15 VA Gen |
|
Pollution Degree |
3 |
|
Protection |
IP20 |
|
Led Indications |
Mains, Gen, Overload |
|
Wiring Termination |
Bottom to Top Wiring |
|
Operating Temperature |
-5 to +55° C |
|
Terminal Capacity |
10mm2 |
|
Reset Provision |
Auto Reset |
|
Tripping Accuracy |
± 10% of Trip Current |
|
Timing Accuracy |
± 5% |
|
Mounting |
Mounting Rail(35x 7.5mm) |
|
Mounting Position |
Vertical/ Horizontalt |
|
Warranty |
As Per Manufacturer Terms & Conditions |
Original: $30.52
-70%$30.52
$9.16
Description
Product Description
-
A changeover device transfers the Load from Mains power supply to the Generator, automatically upon failure of Mains power supply
-
It also functions as a Load limiter with monitoring of the Generator supply, thereby reducing stress on the Generator
Product Specification
|
Brand |
Anchor |
|
Product Type |
Automatic Changeover |
|
Series |
UNO |
|
Product Code | Gen Current Rating(In) |
98600 | 0.5A 98601 | 1A 98602 | 1.5A 98603 | 2.5A 98605 | 4A 98606 | 5A 98607 | 6A 98608 | 9A 98612 | 10A 98609 | 12A 98610 | 15A 98611 | 20A 98613 | 25A 98614 | 30A |
|
Standard Conformity |
IEC 60947-3/ IEC 60947-6 |
|
Poles |
SPN |
|
Mains Current Rating(In) |
30A |
|
Gen Current Rating(In) |
0.5A to 30A |
|
Rated Voltage (Ue) |
240V~AC, 50Hz |
|
Rated Impulse Voltage |
2.5kV |
|
Design |
Contactor Based Design |
|
Housing Material |
Thermoplastic, FR Grade |
|
Class Of Equipment |
PC |
|
Duty |
Continuous |
|
Utilisation Category |
AC22A(IEC 60947-3), AC32A (IEC 60947-6) |
|
Conditional Short-Circuit Current(Inc) |
5kA |
|
Electrical Life |
25000 Operations |
|
Power Losses |
0.2 VA Mains, 15 VA Gen |
|
Pollution Degree |
3 |
|
Protection |
IP20 |
|
Led Indications |
Mains, Gen, Overload |
|
Wiring Termination |
Bottom to Top Wiring |
|
Operating Temperature |
-5 to +55° C |
|
Terminal Capacity |
10mm2 |
|
Reset Provision |
Auto Reset |
|
Tripping Accuracy |
± 10% of Trip Current |
|
Timing Accuracy |
± 5% |
|
Mounting |
Mounting Rail(35x 7.5mm) |
|
Mounting Position |
Vertical/ Horizontalt |
|
Warranty |