Kusam-meco True RMS Digital Insulation Multimeter KM 887
Product Description
-
VFD V & Hz readings
-
LCD Backlight Display
-
Record MAX/MIN regular readings
-
Display Hold Function
-
Dual Display +Hz readings
-
Relative zero mode
-
LOCK-Test mode for Insulation Resistance
-
BeepJack audible & visible input warning
-
High resolution 60.00mV & 60.00 ranges
Product Specification
|
Brand |
Kusam-meco |
|
Product Model |
KM 887 |
|
Product Type |
Insulation Multimeter |
|
Power Supply |
Four Alkaline AA batteries |
|
Power Consumption |
6.5mA Typical Except The Followings : VFD ACV +Hz : 8mA |
|
Operating Temperature |
-10ºC ~ 50ºC |
|
Storage Temperature |
-20 °C ~ 60 °C, < 80% R.H. (With Battery Removed) |
|
Altitude |
Operating Below 2000m |
|
Sensing |
AC, True RMS |
|
Display |
3-5/6 digits 6000 Counts Backlight LCD Display |
|
Update Rate |
5 Per Second Nominal |
|
61 Segments Analog Bar Graph |
40 Per Second Max |
|
Insulation Resistance @ 1mA Test Current |
50V Output Voltage : 25mA 100V
Output Voltage : 45mA 500V
Output Voltage : 170mA |
|
Tester
can perform at least 950 Insulation Tests with new alkaline
batteries at room temperature |
|
|
Temperature Coefficient |
Nominal 0.1 x (Specified Accuracy) / °C @(10ºC~18ºC or 28ºC~50ºC), Or Otherwise Specified |
|
Low Battery |
Approx. 4.6V |
|
APO Timing |
Idle for 20 Minutes |
|
APO Consumption |
20 µA Typical |
|
Polarity |
Automatic |
|
Relative Humidity |
Maximum Relative Humidity 90% For Temperature Up To 28ºC Decreasing Linearly to 50% Relative Humidity at 50ºC |
|
Pollution degree |
2 |
|
IP Rating |
IP40 |
|
Dimension |
208(L) X 103(W) X 64.5(H) mm With Holster |
|
Weight |
635 gm With Holster |
|
Warranty |
As Per Manufacturer Terms and Condition |
Original: $317.41
-70%$317.41
$95.22
Description
Product Description
-
VFD V & Hz readings
-
LCD Backlight Display
-
Record MAX/MIN regular readings
-
Display Hold Function
-
Dual Display +Hz readings
-
Relative zero mode
-
LOCK-Test mode for Insulation Resistance
-
BeepJack audible & visible input warning
-
High resolution 60.00mV & 60.00 ranges
Product Specification
|
Brand |
Kusam-meco |
|
Product Model |
KM 887 |
|
Product Type |
Insulation Multimeter |
|
Power Supply |
Four Alkaline AA batteries |
|
Power Consumption |
6.5mA Typical Except The Followings : VFD ACV +Hz : 8mA |
|
Operating Temperature |
-10ºC ~ 50ºC |
|
Storage Temperature |
-20 °C ~ 60 °C, < 80% R.H. (With Battery Removed) |
|
Altitude |
Operating Below 2000m |
|
Sensing |
AC, True RMS |
|
Display |
3-5/6 digits 6000 Counts Backlight LCD Display |
|
Update Rate |
5 Per Second Nominal |
|
61 Segments Analog Bar Graph |
40 Per Second Max |
|
Insulation Resistance @ 1mA Test Current |
50V Output Voltage : 25mA 100V
Output Voltage : 45mA 500V
Output Voltage : 170mA |
|
Tester
can perform at least 950 Insulation Tests with new alkaline
batteries at room temperature |
|
|
Temperature Coefficient |
Nominal 0.1 x (Specified Accuracy) / °C @(10ºC~18ºC or 28ºC~50ºC), Or Otherwise Specified |
|
Low Battery |
Approx. 4.6V |
|
APO Timing |
Idle for 20 Minutes |
|
APO Consumption |
20 µA Typical |
|
Polarity |
Automatic |
|
Relative Humidity |
Maximum Relative Humidity 90% For Temperature Up To 28ºC Decreasing Linearly to 50% Relative Humidity at 50ºC |
|
Pollution degree |
2 |
|
IP Rating |
IP40 |
|
Dimension |
208(L) X 103(W) X 64.5(H) mm With Holster |
|
Weight |
635 gm With Holster |
|
Warranty |
As Per Manufacturer Terms and Condition |