Fully Automatic operation enabling both draining and filling simultaneously with a single device
-
Adjustable sensitivity level from 1k to 200k Ohm
-
Includes provision for Manual start
-
Protects submersible pumps against dry running and prevents overfilling
-
Enables maximum utilization of incoming liquid (eg. water) supply
-
Specially designed corrosion and shock resistant sensors to ensure trouble-free operation
Product Specification
|
Brand |
GIC |
|
Product Type |
Liquid level Controller |
|
Model |
4421AD1 |
|
Monitoring Function |
Liquid Level Control |
|
Control Action Modes |
Only Draining, Only Filling, Draining & Filling Simultaneous (One Tank or Two tanks) |
|
Sensitivity |
1K to 200 K Ohm (Potentiometer adjustable) |
|
Settable ON & OFF Delay Time |
0.5 sec to 10 sec |
|
Manual Start Switch |
If Lower tank water level is greater than Low level & upper tank water level is below High level th |
|
|
pressing a switch Relay can be switched ON manually. |
|
Output Control Mode |
Relay ON/OFF |
|
Contact Ratings |
1 C/O,8A@250VAC,Resistive,Terminal 15-Pole, Terminal 16-NC,Terminal 18-NO |
|
Electrical Life |
5 1 x 10 Operations |
|
Mechanical Life |
7 1 x 10 Operations |
|
LED Indication |
GREEN LED: Power ON RED LED : Relay Output ON |
|
Operating Temperature |
-10°C to +60°C |
|
Storage Temperature |
-10°C to +70°C |
|
Relative Humidity |
5 to 95 % RH (non condensing) |
|
Mounting |
Base/DIN Rail |
|
Dimension (W x H x D) |
36 X 90 X 65 mm |
|
Weight |
235 g |
Original: $16.37
-70%$16.37
$4.91
Description
Product Description
-
Fully Automatic operation enabling both draining and filling simultaneously with a single device
-
Adjustable sensitivity level from 1k to 200k Ohm
-
Includes provision for Manual start
-
Protects submersible pumps against dry running and prevents overfilling
-
Enables maximum utilization of incoming liquid (eg. water) supply
-
Specially designed corrosion and shock resistant sensors to ensure trouble-free operation
Product Specification
|
Brand |
GIC |
|
Product Type |
Liquid level Controller |
|
Model |
4421AD1 |
|
Monitoring Function |
Liquid Level Control |
|
Control Action Modes |
Only Draining, Only Filling, Draining & Filling Simultaneous (One Tank or Two tanks) |
|
Sensitivity |
1K to 200 K Ohm (Potentiometer adjustable) |
|
Settable ON & OFF Delay Time |
0.5 sec to 10 sec |
|
Manual Start Switch |
If Lower tank water level is greater than Low level & upper tank water level is below High level th |
|
|
pressing a switch Relay can be switched ON manually. |
|
Output Control Mode |
Relay ON/OFF |
|
Contact Ratings |
1 C/O,8A@250VAC,Resistive,Terminal 15-Pole, Terminal 16-NC,Terminal 18-NO |
|
Electrical Life |
5 1 x 10 Operations |
|
Mechanical Life |
7 1 x 10 Operations |
|
LED Indication |
GREEN LED: Power ON RED LED : Relay Output ON |
|
Operating Temperature |
-10°C to +60°C |
|
Storage Temperature |
-10°C to +70°C |
|
Relative Humidity |
5 to 95 % RH (non condensing) |
|
Mounting |
Base/DIN Rail |
|
Dimension (W x H x D) |
36 X 90 X 65 mm |
|
Weight |
235 g |