HomeStore

Fluke iFlex Flexible Current Probes i2500-18

Fluke iFlex Flexible Current Probes i2500-18

Product Description

  • Expands the Measurement Range to 2500 A AC while Providing Increased Display Flexibility, Ability to Measure Awkward Sized Conductors and Improved Wire Access

  • CAT IV 600 V, CAT III 1000 V

  • 7.5 mm Coil Diameter Allows Measurement in Tight Spaces

  • Ergonomic Design Allows Easy Operation with One Hand

  • 1.8 m (6 ft) Cable

Product Specification

Brand

Fluke

Product Type

Current Probes

Model

i2500-18


Range

Resolution

Accuracy

AC Current1

2500 A

0.1 A

3% ± 5 digits2

Frequency1

500 Hz

0.1 Hz

0.5% ± 5 digits

External Magnetic Field Rejection
(With Cable >10 cm From The Coupling)

40 dB

Inrush1

Safety Rating

CAT III 1000 V, CAT IV 600 V

When used with compatible Fluke meter

Accuracy stated includes probe and meter accuracy
For position accuracy at non-optimum positions, see Position sensitivity specifications table “A”

Position Sensitivity Specifications


Distance From Optimum

i2500-18

A

1.4 in (35.6 mm)

B

2.0 in (50.8 mm)

C

2.5 in (63.5 mm)

Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature

Warranty

3 Years

$155.95
Fluke iFlex Flexible Current Probes i2500-18
$155.95
Product image 1

Description

Product Description

  • Expands the Measurement Range to 2500 A AC while Providing Increased Display Flexibility, Ability to Measure Awkward Sized Conductors and Improved Wire Access

  • CAT IV 600 V, CAT III 1000 V

  • 7.5 mm Coil Diameter Allows Measurement in Tight Spaces

  • Ergonomic Design Allows Easy Operation with One Hand

  • 1.8 m (6 ft) Cable

Product Specification

Brand

Fluke

Product Type

Current Probes

Model

i2500-18


Range

Resolution

Accuracy

AC Current1

2500 A

0.1 A

3% ± 5 digits2

Frequency1

500 Hz

0.1 Hz

0.5% ± 5 digits

External Magnetic Field Rejection
(With Cable >10 cm From The Coupling)

40 dB

Inrush1

Safety Rating

CAT III 1000 V, CAT IV 600 V

When used with compatible Fluke meter

Accuracy stated includes probe and meter accuracy
For position accuracy at non-optimum positions, see Position sensitivity specifications table “A”

Position Sensitivity Specifications


Distance From Optimum

i2500-18

A

1.4 in (35.6 mm)

B

2.0 in (50.8 mm)

C

2.5 in (63.5 mm)

Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature

Warranty

3 Years

Fluke iFlex Flexible Current Probes i2500-18 | Bestomart