  • Residual Current Circuit Breaker (RCCB) also called Earth Leakage Circuit Breaker (ELCB) is a device designed to disconnect the load from the supply mains, when the residual current (I∆n) is flowing in the circuit

  • The flow of currents in the electrical system is risky

  • Low quality faulty wires, poorly insulated equipments or incorrect use of electrical devices cause current to flow through the wrong path to the earth

  • This current is called “Leakage Current”

  • Features

  • Elegant appearance

  • Advance Neutral breaks after phases, ensuring complete discharge

  • No nuisance tripping

  • Fastest Tripping Mechanism

  • Bi-connect terminals for bus bar as well as cable connections

  • IP 20 protection finger touch proof connection terminals as well

  • Truly current operated, operates even at very low voltage

  • High short current withstand capacity

  • Large terminal size 35 sq mm

  • Manufactured in accordance with IS 12640 Part I

  • Flame retardant body and cover, does not melt / drip even at high temperature

Product Specification

Brand

Anchor

Product Type

RCCB

Product Code | Specification

98201 | 25A DP 30mA

98202 | 25A DP 100mA

98203 | 25A DP 300mA

98207 | 40A DP 30mA

98208 | 40A DP 100mA

98209 | 40A DP 300mA

98210 | 63A DP 30mA

98211 | 63A DP 100mA

98212 | 63A DP 300mA

Series

UNO

Reference Standard

IS 12640 -1:2000, IEC 61008

Poles

DP

Current Rating (In)

25A, 40A & 63A

Rated Voltage (Ue)

240/415V~ AC

Rated Residual Operating Current(I∆n)

30mA, 100mA & 300mA

Protection

Against Earth fault / Leakage Current

Operating Device

Current operating device

Rated Frequency(f)

50Hz

Rated Insulation Voltage(Ui)

440 V

Rated Conditional Short Circuit Current(Inc)

6kA

Rated Making Capacity(I∆m)

500A or 10In whichever is greater

Operating Characteristic

AC’ Type

Dielectric Strength

2.5 kV

Trip Time

Instantaneous < 40ms, Selective > 150ms

Operating Temperature

-5 to 50 ºC

Terminal Capacity

35 mm2 (max.) copper

Relative Humidity

95%

Vibration

3g

Protection Class

IP 20

Contact Position Indication

Yes

Installation Position

Vertical / Horizontal

Mounting

Clip on Din rail ( 35 mm * 7.5 mm)

Warranty

As Per Manufacturer Terms & Conditions

Select Product Code | Specification
From $8.51

Original: $28.35

-70%
Anchor UNO Residual Current Circuit Breaker (RCCB) 2 Poles

$28.35

$8.51
Product image 1

Description

Product Description

  • Residual Current Circuit Breaker (RCCB) also called Earth Leakage Circuit Breaker (ELCB) is a device designed to disconnect the load from the supply mains, when the residual current (I∆n) is flowing in the circuit

  • The flow of currents in the electrical system is risky

  • Low quality faulty wires, poorly insulated equipments or incorrect use of electrical devices cause current to flow through the wrong path to the earth

  • This current is called “Leakage Current”

  • Features

  • Elegant appearance

  • Advance Neutral breaks after phases, ensuring complete discharge

  • No nuisance tripping

  • Fastest Tripping Mechanism

  • Bi-connect terminals for bus bar as well as cable connections

  • IP 20 protection finger touch proof connection terminals as well

  • Truly current operated, operates even at very low voltage

  • High short current withstand capacity

  • Large terminal size 35 sq mm

  • Manufactured in accordance with IS 12640 Part I

  • Flame retardant body and cover, does not melt / drip even at high temperature

Product Specification

Brand

Anchor

Product Type

RCCB

Product Code | Specification

98201 | 25A DP 30mA

98202 | 25A DP 100mA

98203 | 25A DP 300mA

98207 | 40A DP 30mA

98208 | 40A DP 100mA

98209 | 40A DP 300mA

98210 | 63A DP 30mA

98211 | 63A DP 100mA

98212 | 63A DP 300mA

Series

UNO

Reference Standard

IS 12640 -1:2000, IEC 61008

Poles

DP

Current Rating (In)

25A, 40A & 63A

Rated Voltage (Ue)

240/415V~ AC

Rated Residual Operating Current(I∆n)

30mA, 100mA & 300mA

Protection

Against Earth fault / Leakage Current

Operating Device

Current operating device

Rated Frequency(f)

50Hz

Rated Insulation Voltage(Ui)

440 V

Rated Conditional Short Circuit Current(Inc)

6kA

Rated Making Capacity(I∆m)

500A or 10In whichever is greater

Operating Characteristic

AC’ Type

Dielectric Strength

2.5 kV

Trip Time

Instantaneous < 40ms, Selective > 150ms

Operating Temperature

-5 to 50 ºC

Terminal Capacity

35 mm2 (max.) copper

Relative Humidity

95%

Vibration

3g

Protection Class

IP 20

Contact Position Indication

Yes

Installation Position

Vertical / Horizontal

Mounting

Clip on Din rail ( 35 mm * 7.5 mm)