HomeStore

ABB OVR Surge Protective Device Spark Gap Type

ABB OVR Surge Protective Device Spark Gap Type

Product Description

  • Type 1 SPDs can be installed at the entrance in the main switch board for protection of electrical installation and equipments against direct lightning surges

  • Product Name : Surge Protective Device

  • Product Main Type : T1

  • Product Type : QS

  • Product Net Width : 160,2 mm

  • Product Net Height :90 mm

  • Product Net Depth / Length : 64,8 mm

  • Product Net Weight :500 g

  • Number of Protected Poles : 4

  • Voltage Rating DC : 350 V

  • Short Circuit Withstand Icc : 50 kA

  • Impulse Current : I (imp, 10 / 350 µs) 2 kA , I (total, 10 / 350 µs) 25 kA

  • Discharge Current : Nominal 25 kA , Maximum 60 kA

  • Nominal AC Voltage of the System (Uo) : 230 / 400 V

  • Version : Fix

  • Suitable For : To protect the systems against the transient overvoltage (lightning)

  • Standards : IEC 61643-11 / EN 61643-11

Product Specification

Max. Voltage Uc (V)

I max in kA

( 8/20us wave)

No of Modules

Product Id

Type

255

60

5

2CTB815101R8800

OVR T1 3N 25 255-7

275

80

4

2CTB815710R1900

OVR T1-T2 3N 12.5- 275s P QS

275

80

4

2CTB815710R0700

OVR T1-T2 3N 12.5- 275s P TS QS

440

80

4

2CTB815710R4800

OVR T1-T2 3N 12.5- 440s P QS

440

80

4

2CTB815710R3600

OVR T1-T2 3N 12.5- 440s P TS QS

Select Product id
From $68.41

Original: $228.02

-70%
ABB OVR Surge Protective Device Spark Gap Type

$228.02

$68.41
Product image 1

Description

Product Description

  • Type 1 SPDs can be installed at the entrance in the main switch board for protection of electrical installation and equipments against direct lightning surges

  • Product Name : Surge Protective Device

  • Product Main Type : T1

  • Product Type : QS

  • Product Net Width : 160,2 mm

  • Product Net Height :90 mm

  • Product Net Depth / Length : 64,8 mm

  • Product Net Weight :500 g

  • Number of Protected Poles : 4

  • Voltage Rating DC : 350 V

  • Short Circuit Withstand Icc : 50 kA

  • Impulse Current : I (imp, 10 / 350 µs) 2 kA , I (total, 10 / 350 µs) 25 kA

  • Discharge Current : Nominal 25 kA , Maximum 60 kA

  • Nominal AC Voltage of the System (Uo) : 230 / 400 V

  • Version : Fix

  • Suitable For : To protect the systems against the transient overvoltage (lightning)

  • Standards : IEC 61643-11 / EN 61643-11

Product Specification

Max. Voltage Uc (V)

I max in kA

( 8/20us wave)

No of Modules

Product Id

Type

255

60

5

2CTB815101R8800

OVR T1 3N 25 255-7

275

80

4

2CTB815710R1900

OVR T1-T2 3N 12.5- 275s P QS

275

80

4

2CTB815710R0700

OVR T1-T2 3N 12.5- 275s P TS QS

440

80

4

2CTB815710R4800

OVR T1-T2 3N 12.5- 440s P QS

440

80

4

2CTB815710R3600

OVR T1-T2 3N 12.5- 440s P TS QS