ABB MO165-80 Manual Motor Starter Magnetic Only 1SAM461000R1019

ABB MO165-80 Manual Motor Starter Magnetic Only 1SAM461000R1019

Product Description

  • The MO165 manual Motor starter magnetic only is a compact and powerful range for Motor protection up To 45 kW (400 V) in width Of 55 mm

  • The devices are used To manually switch on and Off loads/Motors and To protect them reliably and without the need for a fuse from short-circuits

  • The manual Motor starter Offers a rated service short-circuit breaking capacity up To 100 kA at 400 V AC. A combination Together with overload relays or Motor controllers allows the protection Of Motors

  • Further features are the built-in disconnect function, trip-free mechanism and a rotary handle with a clear switch position indication

  • The manual Motor starters magnetic only are suitable for three- and single-phase applications

  • The handle is lockable To protect against unauthorized changes

  • Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars and power in-feed blocks are available as Accessory

Product Specification

Brand

ABB

Product Type

Manual Motor Starter

Product Code

1SAM461000R1019

Model

MO165-80

Technical

Rated Service Short-Circuit Breaking Capacity (Ics)

(230 V AC) 30 kA, (250 V DC) 3 Poles in Series 100 kA, (400 V AC) 30 kA, (440 V AC) 18 kA, (500 V AC) 10 kA, (690 V AC) 6 kA

Rated Ultimate Short-Circuit Breaking Capacity (Icu)

(230 V AC) 30 kA, (250 V DC) 100 kA, (400 V AC) 30 kA, (440 V AC) 18 kA, ( 500 V AC) 10 kA, (690 V AC) 8 kA

Rated Instantaneous Short-Circuit Current Setting (Ii)

1120 A

Setting Range

None

Rated Operational Power AC-3 (Pe)

(400 V) Three Phase 45 kW

Rated Operational Power AC-3e (Pe)

(400 V) Three Phase 45 kW

Rated Operational Voltage

Main Circuit 690 V AC, Main Circuit 250 V DC

Rated Operational Current (Ie)

80 A

Rated Operational Current AC-3 (Ie)

80 A

Rated Operational Current AC-3e (Ie)

80 A

Rated Operational Current DC-5 (Ie)

80 A

Rated Frequency (f)

Main Circuit 50 Hz, Main Circuit 60 Hz

Rated Impulse Withstand Voltage (Uimp)

Main Circuit 8 kV

Rated Insulation Voltage (Ui)

1000 V

Power Loss

at Rated Operating Conditions per Pole 5.22 W

Number Of Poles

3

Conventional Free-air Thermal Current (Ith)

Main Circuit 80 A

Degree Of Protection

Housing IP20, Main Circuit Terminals IP10

Pollution Degree

3

Electrical Durability

20000 cycle

Mechanical Durability

50000 cycle

Terminal Type

Screw Terminals

Connecting Capacity Main Circuit

Flexible with Ferrule 1/2x 1 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²
Flexible 1/2x 1 ... 35 mm²
Rigid 1/2x 1 ... 4 mm²
Solid 1/2x 1 ... 4 mm²
Stranded 1/2x 1 ... 50 mm²

Tightening Torque

Main Circuit 4 N·m

Wire Stripping Length

Main Circuit 16 mm

Recommended Screw Driver

Pozidriv 2

Mounting Position

Position 1 To 6

Mounting On DIN Rail

TH35-15 (35 x 15 mm Mounting Rail) Acc. To IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) Acc. To IEC 60715

Minimum Mounting Distance

Electrical Conductive Board, Horizontal - Up To 1000 V 1.5 mm
Electrical Conductive Board, Horizontal - Up To 400 V 0 mm
Electrical Conductive Board, Horizontal - Up To 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm

Actuator Type

Rotary Handle

Contact Position Indication

ON / OfF / TRIP

Standards

CSA 22.2 No. 14, IEC/EN 60947-1, IEC/EN 60947-2,
IEC/EN 60947-4-1, UL 60947-4-1

Remarks

For overload protection Of the Motors, an appropriate thermal or electronic overload relays must be used

Technical UL/CSA

Short-Circuit Current Rating (SCCR)

Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 50 kA, (600 V AC) 10 kA

Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 50 kA, (600 V AC) 10 kA
Any UL Listed Fuses or Circuit-Breakers, Tap ConducTor Protection in Group Installations (480Y / 277 V AC) 50 kA, (600Y / 347 V AC) 10 kA

Maximum Operating Voltage UL/CSA

Main Circuit 600 V AC

Ampere Rating UL/CSA

80 A

Horsepower Rating UL/CSA

(200 V AC) Three Phase 20 Hp
(208 V AC) Three Phase 20 Hp
(220 ... 240 V AC) Three Phase 25 Hp
(440 ... 480 V AC) Three Phase 50 Hp
(550 ... 600 V AC) Three Phase 60 Hp

Full Load Amps Motor Use

(110 ... 120 V AC) Three Phase 56 A
(200 V AC) Three Phase 62.1 A
(208 V AC) Three Phase 59.4 A
(220 ... 240 V AC) Three Phase 68 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A

Locked RoTor Amps

(200 V AC) Three Phase 334 A
(208 V AC) Three Phase 321 A
(220 ... 240 V AC) Three Phase 365 A
(440 ... 480 V AC) Three Phase 363 A
(550 ... 600 V AC) Three Phase 348 A

General Use Rating UL/CSA

(600 V AC) 80 A

Connecting Capacity Main Circuit UL/CSA

Flexible 1/2x 16-0 AWG, Stranded 1/2x 16-0 AWG

Tightening Torque UL/CSA

Main Circuit 35 in·lb

Environmental

Ambient Air Temperature

Operation -25 ... +60 °C
Operation Compensated -25 ... +60 °C
STorage -50 ... +80 °C

Ambient Air Temperature Compensation

No

Maximum Operating Altitude Permissible

2000 m

Resistance To Shock Acc. To IEC 60068-2-27

11 ms Pulse 25g

Resistance To Vibrations Acc. To IEC 60068-2-6

5g / 3 ... 150 Hz

Dimensions

Product Net Width

55 mm

Product Net Height

142.65 mm

Product Net Depth / Length

122 mm

Product Net Weight

1 kg

Warranty

As Per Manufacturer Terms and Condition

$62.76

Original: $209.19

-70%
ABB MO165-80 Manual Motor Starter Magnetic Only 1SAM461000R1019

$209.19

$62.76
Product image 1

Description

Product Description

  • The MO165 manual Motor starter magnetic only is a compact and powerful range for Motor protection up To 45 kW (400 V) in width Of 55 mm

  • The devices are used To manually switch on and Off loads/Motors and To protect them reliably and without the need for a fuse from short-circuits

  • The manual Motor starter Offers a rated service short-circuit breaking capacity up To 100 kA at 400 V AC. A combination Together with overload relays or Motor controllers allows the protection Of Motors

  • Further features are the built-in disconnect function, trip-free mechanism and a rotary handle with a clear switch position indication

  • The manual Motor starters magnetic only are suitable for three- and single-phase applications

  • The handle is lockable To protect against unauthorized changes

  • Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars and power in-feed blocks are available as Accessory

Product Specification

Brand

ABB

Product Type

Manual Motor Starter

Product Code

1SAM461000R1019

Model

MO165-80

Technical

Rated Service Short-Circuit Breaking Capacity (Ics)

(230 V AC) 30 kA, (250 V DC) 3 Poles in Series 100 kA, (400 V AC) 30 kA, (440 V AC) 18 kA, (500 V AC) 10 kA, (690 V AC) 6 kA

Rated Ultimate Short-Circuit Breaking Capacity (Icu)

(230 V AC) 30 kA, (250 V DC) 100 kA, (400 V AC) 30 kA, (440 V AC) 18 kA, ( 500 V AC) 10 kA, (690 V AC) 8 kA

Rated Instantaneous Short-Circuit Current Setting (Ii)

1120 A

Setting Range

None

Rated Operational Power AC-3 (Pe)

(400 V) Three Phase 45 kW

Rated Operational Power AC-3e (Pe)

(400 V) Three Phase 45 kW

Rated Operational Voltage

Main Circuit 690 V AC, Main Circuit 250 V DC

Rated Operational Current (Ie)

80 A

Rated Operational Current AC-3 (Ie)

80 A

Rated Operational Current AC-3e (Ie)

80 A

Rated Operational Current DC-5 (Ie)

80 A

Rated Frequency (f)

Main Circuit 50 Hz, Main Circuit 60 Hz

Rated Impulse Withstand Voltage (Uimp)

Main Circuit 8 kV

Rated Insulation Voltage (Ui)

1000 V

Power Loss

at Rated Operating Conditions per Pole 5.22 W

Number Of Poles

3

Conventional Free-air Thermal Current (Ith)

Main Circuit 80 A

Degree Of Protection

Housing IP20, Main Circuit Terminals IP10

Pollution Degree

3

Electrical Durability

20000 cycle

Mechanical Durability

50000 cycle

Terminal Type

Screw Terminals

Connecting Capacity Main Circuit

Flexible with Ferrule 1/2x 1 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²
Flexible 1/2x 1 ... 35 mm²
Rigid 1/2x 1 ... 4 mm²
Solid 1/2x 1 ... 4 mm²
Stranded 1/2x 1 ... 50 mm²

Tightening Torque

Main Circuit 4 N·m

Wire Stripping Length

Main Circuit 16 mm

Recommended Screw Driver

Pozidriv 2

Mounting Position

Position 1 To 6

Mounting On DIN Rail

TH35-15 (35 x 15 mm Mounting Rail) Acc. To IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) Acc. To IEC 60715

Minimum Mounting Distance

Electrical Conductive Board, Horizontal - Up To 1000 V 1.5 mm
Electrical Conductive Board, Horizontal - Up To 400 V 0 mm
Electrical Conductive Board, Horizontal - Up To 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm

Actuator Type

Rotary Handle

Contact Position Indication

ON / OfF / TRIP

Standards

CSA 22.2 No. 14, IEC/EN 60947-1, IEC/EN 60947-2,
IEC/EN 60947-4-1, UL 60947-4-1

Remarks

For overload protection Of the Motors, an appropriate thermal or electronic overload relays must be used

Technical UL/CSA

Short-Circuit Current Rating (SCCR)

Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 50 kA, (600 V AC) 10 kA

Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 50 kA, (600 V AC) 10 kA
Any UL Listed Fuses or Circuit-Breakers, Tap ConducTor Protection in Group Installations (480Y / 277 V AC) 50 kA, (600Y / 347 V AC) 10 kA

Maximum Operating Voltage UL/CSA

Main Circuit 600 V AC

Ampere Rating UL/CSA

80 A

Horsepower Rating UL/CSA

(200 V AC) Three Phase 20 Hp
(208 V AC) Three Phase 20 Hp
(220 ... 240 V AC) Three Phase 25 Hp
(440 ... 480 V AC) Three Phase 50 Hp
(550 ... 600 V AC) Three Phase 60 Hp

Full Load Amps Motor Use

(110 ... 120 V AC) Three Phase 56 A
(200 V AC) Three Phase 62.1 A
(208 V AC) Three Phase 59.4 A
(220 ... 240 V AC) Three Phase 68 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A

Locked RoTor Amps

(200 V AC) Three Phase 334 A
(208 V AC) Three Phase 321 A
(220 ... 240 V AC) Three Phase 365 A
(440 ... 480 V AC) Three Phase 363 A
(550 ... 600 V AC) Three Phase 348 A

General Use Rating UL/CSA

(600 V AC) 80 A

Connecting Capacity Main Circuit UL/CSA

Flexible 1/2x 16-0 AWG, Stranded 1/2x 16-0 AWG

Tightening Torque UL/CSA

Main Circuit 35 in·lb

Environmental

Ambient Air Temperature

Operation -25 ... +60 °C
Operation Compensated -25 ... +60 °C
STorage -50 ... +80 °C

Ambient Air Temperature Compensation

No

Maximum Operating Altitude Permissible

2000 m

Resistance To Shock Acc. To IEC 60068-2-27

11 ms Pulse 25g

Resistance To Vibrations Acc. To IEC 60068-2-6

5g / 3 ... 150 Hz

Dimensions

Product Net Width

55 mm

Product Net Height

142.65 mm

Product Net Depth / Length

122 mm

Product Net Weight

1 kg

Warranty

As Per Manufacturer Terms and Condition

ABB MO165-80 Manual Motor Starter Magnetic Only 1SAM461000R1019 | Bestomart