HomeStore

ABB ESB25-40N-01 Installation Contactor 1SAE231111R0140

ABB ESB25-40N-01 Installation Contactor 1SAE231111R0140

Product Description

  • The ESB25..N installation contactors are used to control single and three-phase loads up to 25 A and can be operated by AC or DC

  • These contactors are made for use in household applications as well as in industrial environments

  • The following benefits are provided:

  • Hum-free operation, low power consumption and integrated overvoltage protection

  • Various contact combinations and accessories are available

Product Specification

Brand

ABB

Product Type

Installation Contactor

Product Code

1SAE231111R0140

Model

ESB25-40N-01

Technical

Rated Operational Voltage

Main Circuit 220 V DC, Main Circuit 400 V AC

Rated Control Circuit Voltage (Uc)

24 V

Rated Frequency (f)

Control Circuit 400 Hz, Control Circuit 50 Hz, Control Circuit 60 Hz, Control Circuit DC, Main Circuit 50 Hz, Main Circuit 60 Hz, Main Circuit DC

Rated Operational Current AC-1 (Ie)

(NO) 25 A

Rated Operational Current AC-3 (Ie)

(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A

Rated Operational Power AC-1 (Pe)

(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW

Rated Operational Power AC-3 (Pe)

(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW

Rated Operational Power AC-7a (Pe)

(NO) 25 A

Rated Operational Power AC-7a (Pe)

(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW

Rated Operational Current AC-7b (Ie)

(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A

Rated Operational Power AC-7b (Pe)

(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW

Recommended Screw Driver

Control Circuit Pozidriv 1, Main Circuit Pozidriv 1

Rated Impulse Withstand Voltage (Uimp)

6 kV

Rated Insulation Voltage (Ui)

500 V

Connecting Capacity Main Circuit

Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²

Connecting Capacity Control Circuit

Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²

Tightening Torque

Control Circuit 0.9 N·m, Main Circuit 1 N·m

Wire Stripping Length

Control Circuit 7 mm, Main Circuit 10 mm

Degree Of Protection

IP20

Electrical Durability

AC-1 (NO) 130000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NO) 500000 cycle

Mechanical Durability

1000000 cycle

Number Of Poles

4

Number Of Auxiliary Contacts NC

0

Number Of Auxiliary Contacts NO

0

Number Of Main Contacts NC

0

Number Of Main Contacts NO

4

Width In Number Of Modular Spacings

2

Pollution Degree

3

Standards

IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1

Technical UL/CSA

Maximum Operating Voltage UL/CSA

Main Circuit 480 V AC

Horsepower Rating UL/CSA

(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NO 5 Hp

Connecting Capacity Main Circuit UL/CSA

Solid 16-8 AWG, Stranded 16-8 AWG

Connecting Capacity Control Circuit UL/CSA

Solid 16-10 AWG, Stranded 16-10 AWG

Tightening Torque UL/CSA

Control Circuit 8 in·lb, Main Circuit 9 in·lb

Environmental

Ambient Air Temperature

Operation -25 ... +55 °C
Storage -40 ... +80 °C

Maximum Operating Altitude Permissible

2000 m

Resistance To Shock Acc. To IEC 60068-2-27

11 ms Pulse 15g

Dimensions

Product Net Width

36 mm

Product Net Height

85 mm

Product Net Depth / Length

65 mm

Product Net Weight

0.245 kg

Warranty

As Per Manufacturer Terms and Condition

$45.56
ABB ESB25-40N-01 Installation Contactor 1SAE231111R0140
$45.56
Product image 1

Description

Product Description

  • The ESB25..N installation contactors are used to control single and three-phase loads up to 25 A and can be operated by AC or DC

  • These contactors are made for use in household applications as well as in industrial environments

  • The following benefits are provided:

  • Hum-free operation, low power consumption and integrated overvoltage protection

  • Various contact combinations and accessories are available

Product Specification

Brand

ABB

Product Type

Installation Contactor

Product Code

1SAE231111R0140

Model

ESB25-40N-01

Technical

Rated Operational Voltage

Main Circuit 220 V DC, Main Circuit 400 V AC

Rated Control Circuit Voltage (Uc)

24 V

Rated Frequency (f)

Control Circuit 400 Hz, Control Circuit 50 Hz, Control Circuit 60 Hz, Control Circuit DC, Main Circuit 50 Hz, Main Circuit 60 Hz, Main Circuit DC

Rated Operational Current AC-1 (Ie)

(NO) 25 A

Rated Operational Current AC-3 (Ie)

(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A

Rated Operational Power AC-1 (Pe)

(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW

Rated Operational Power AC-3 (Pe)

(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW

Rated Operational Power AC-7a (Pe)

(NO) 25 A

Rated Operational Power AC-7a (Pe)

(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW

Rated Operational Current AC-7b (Ie)

(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A

Rated Operational Power AC-7b (Pe)

(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW

Recommended Screw Driver

Control Circuit Pozidriv 1, Main Circuit Pozidriv 1

Rated Impulse Withstand Voltage (Uimp)

6 kV

Rated Insulation Voltage (Ui)

500 V

Connecting Capacity Main Circuit

Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²

Connecting Capacity Control Circuit

Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²

Tightening Torque

Control Circuit 0.9 N·m, Main Circuit 1 N·m

Wire Stripping Length

Control Circuit 7 mm, Main Circuit 10 mm

Degree Of Protection

IP20

Electrical Durability

AC-1 (NO) 130000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NO) 500000 cycle

Mechanical Durability

1000000 cycle

Number Of Poles

4

Number Of Auxiliary Contacts NC

0

Number Of Auxiliary Contacts NO

0

Number Of Main Contacts NC

0

Number Of Main Contacts NO

4

Width In Number Of Modular Spacings

2

Pollution Degree

3

Standards

IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1

Technical UL/CSA

Maximum Operating Voltage UL/CSA

Main Circuit 480 V AC

Horsepower Rating UL/CSA

(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NO 5 Hp

Connecting Capacity Main Circuit UL/CSA

Solid 16-8 AWG, Stranded 16-8 AWG

Connecting Capacity Control Circuit UL/CSA

Solid 16-10 AWG, Stranded 16-10 AWG

Tightening Torque UL/CSA

Control Circuit 8 in·lb, Main Circuit 9 in·lb

Environmental

Ambient Air Temperature

Operation -25 ... +55 °C
Storage -40 ... +80 °C

Maximum Operating Altitude Permissible

2000 m

Resistance To Shock Acc. To IEC 60068-2-27

11 ms Pulse 15g

Dimensions

Product Net Width

36 mm

Product Net Height

85 mm

Product Net Depth / Length

65 mm

Product Net Weight

0.245 kg

Warranty